DIN rail modules
Chapter 4
The heart of the system, in the electrical panel.
The heart of the KNX system beats in the distribution board.

The whole range on DIN rail
Build your panel.
Choose the modules: they snap onto the rail at real scale, with the list of codes ready to copy.
File
MU per row
0 / 72 UM
24 free MU
24 free MU
24 free MU
Your panel
- The panel is empty: add the modules from the list below.
Add modules
Tap a module to add it to the panel · drag the modules in the panel to reorder them · tap them to remove them or open their data sheet.
01 DIN rail modules
Bus power supplies.
Compare the models.
| 2 models | ||
|---|---|---|
| Max number of KNX devices connectable on the KNX bus power line | 256 | 64 |
| Button for resetting the connected bus line | ||
| KNX bus operation status LED | ||
| KNX bus overload status LED | ||
| Integrated decoupling choke | ||
| Primary power supply 230 Vac | ||
| Primary power supply 180 - 264 Vac, 176 - 280 Vdc | ||
| Primary power supply 180 - 264 Vac, 254 - 370 Vdc | ||
| Auxiliary power supply output 30 Vdc | ||
| Mounting on 35 mm standard rail (EN 60715) |
| 2 models | ||
|---|---|---|
| AC input 100-240 Vac Full Range and DC input from 110 – 350 Vdc | ||
| Efficiency higher than 85% | ||
| No-load consumption <0.5 W | ||
| Adjustable output voltage | ||
| Natural convection ventilation | ||
| Overload, overtemperature and short-circuit protection | ||
| Input protection with internal fuse | ||
| Can be installed on 35 mm DIN rail (EN 60715) | ||
| Series connection max. 2 units | ||
| Parallel connection (power increase) | ||
| Flame-retardant plastic housing UL94V-0 | ||
| Output voltage = 12 Vdc | ||
| Output current (at 230 Vac) = 2 A | ||
| Output current (at 110 Vac) = 2 A | ||
| Output voltage adjustment = 12-14 Vdc | ||
| Output voltage = 24 Vdc | ||
| Output current (at 230 Vac) = 1 A | ||
| Output current (at 110 Vac) = 1 A | ||
| Output voltage adjustment = 24-28 Vdc |
02 DIN rail modules
System modules.
Compare the models.
| 3 models | |||
|---|---|---|---|
| Suppress device configuration on the sub line | |||
| Enable or disable filtering of group messages | |||
| Suppression of device-oriented messages | |||
| Tracking of traffic on the secondary line and reduction of the number of retransmissions | |||
| Manual function push-button | |||
| KNX operation/fault status LED | |||
| Ethernet operation/fault status LED | |||
| Mounting on 35 mm standard rail (EN 60715) | |||
| Physical address programming button | |||
| Connection of a PC or laptop to the KNX bus system | |||
| Connection to LAN systems | |||
| Secure functions | |||
| Time programming (daily, weekly, monthly or annual) or astronomical programming | |||
| Control of 9 channels on bus | |||
| Channel 1 can be replicated on the on-board relay | |||
| LCD display | |||
| Backup battery | |||
| Optional GPS module connection |
03 DIN rail modules
Flush-mounted I/O modules.
Compare the models.
| 5 models | |||||
|---|---|---|---|---|---|
| Input channels [DI] | 4 | 2 | 4 | 3 | |
| Channels configurable as input [DI] or output [DO] for low-consumption LEDs | 4 | ||||
| Input channels configurable as [AI] for NTC probes or [DI] | 4 | 1 | |||
| Input channels for connecting current transformers EK-TA-... | |||||
| Low-consumption LED output channels | 2 | 4 | 4 | ||
| Relay output channels (5 A) | 2 | ||||
| ON/OFF switching of single loads or group of loads | |||||
| Dimming control of lighting devices | |||||
| Control of roller blinds (shutters, Venetian blinds, curtains, etc.) | |||||
| Detection of the status of signalling contacts | |||||
| Sending and storing scenes | |||||
| Logic functions (AND, OR or XOR) with 4 inputs |
04 DIN rail modules
I/O modules and actuators.
Compare the models.
| 7 models 1–6 of 7 | |||||||
|---|---|---|---|---|---|---|---|
| ON/OFF switching of single loads or group of loads | |||||||
| Configuration of individual outputs as normally open or normally closed | |||||||
| Logic gates and forced operation for each channel | |||||||
| Manual control via microswitch | |||||||
| Manual control via levers (even without voltage on the bus) | |||||||
| Output status indication via lever position | |||||||
| Status indication of outputs via LEDs | |||||||
| Manual/automatic mode switch button | |||||||
| Lock function for each channel | |||||||
| Auxiliary power supply 230 Vac | |||||||
| Switch-off and switch-on delays and staircase lights | |||||||
| Scene management | |||||||
| Operating hours counter configurable via bus | |||||||
| Roller shutter/Venetian blind operating mode | |||||||
| Automatic control for protection against direct sunlight | |||||||
| Automatic control for protection against weather conditions (rain, wind, frost) | |||||||
| Mounting on 35 mm standard rail (EN 60715) |
05 DIN rail modules
Dimmers.
Compare the models.
| 6 models | ||||||
|---|---|---|---|---|---|---|
| ON/OFF switching of single loads or group of loads | ||||||
| Light intensity control | ||||||
| White light tone adjustment (Tunable White) | ||||||
| Logic gates and forced operation for each channel | ||||||
| Manual control via membrane push-buttons | (1) | (1) | (1) | |||
| Status indication of outputs via LEDs | (1) | (1) | (1) | (1) | (1) | |
| Lock function for each channel | ||||||
| No auxiliary power supply required | ||||||
| Switch-off and switch-on delays and staircase lights | ||||||
| Scene management | ||||||
| Operating hours counter configurable via bus | ||||||
| Adjustable fade ramps | ||||||
| Control in RGB / HSV mode | ||||||
| Mounting on 35 mm standard rail (EN 60715) | (2) | (2) |
06 DIN rail modules
DALI dimmers.
Compare the models.
| 5 models | |||||
|---|---|---|---|---|---|
| Memory function | |||||
| Brightness adjustment down to complete switch-off | |||||
| Local control input | |||||
| PWM modulation with adjustable frequency (390 / 3000 / 10000 Hz) | (1) | (1) | |||
| Adjustable dimming curve: linear / logarithmic | |||||
| Soft switch-on and switch-off | |||||
| Optimised output curve | |||||
| Screw terminals for DALI bus, control, power supply and LED source | (2) | ||||
| Device power supply: 8 Vdc (min)... 52.8 Vdc (max) | |||||
| Device power supply: 90-230 Vac 50/60 Hz |
07 DIN rail modules
Temperature control.
Compare the models.
| 6 models | ||||||
|---|---|---|---|---|---|---|
| 30 Vdc power supply from KNX bus | ||||||
| Auxiliary power supply 230 Vac 50/60 Hz | ||||||
| Analogue inputs (passive NTC temperature probes 10 kΩ at 25 °C) | ||||||
| Digital inputs (potential-free) | ||||||
| Relay outputs | ||||||
| TRIAC outputs | ||||||
| 0-10 V output (high-impedance control signal) | ||||||
| Membrane keypad for manual/automatic control with status LEDs | ||||||
| LCD display | ||||||
| Systems with 2-pipe hydraulic distribution | ||||||
| Systems with 4-pipe hydraulic distribution | ||||||
| Actuator | ||||||
| Internal controller | ||||||
| Air terminal: ventilation unit | ||||||
| Air terminal: convector | ||||||
| Air terminal: fan coil | ||||||
| VRF/VRV | ||||||
| Air terminal: fan coil + second electric stage | ||||||
| Floor and ceiling radiant panel systems | ||||||
| Systems with mixing for floor and ceiling radiant panels | ||||||
| Mounting on 35 mm standard rail (EN 60715) |
08 DIN rail modules
Gateways.
Compare the models.
| 9 models 1–5 of 9 | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Power supply | |||||||||
| Isolated RS485 serial communication port | |||||||||
| Line terminator (120 Ohm) enabled via 1-way switch | |||||||||
| Modbus master RTU (Remote Terminal Unit) communication | |||||||||
| BACnet slave communication | |||||||||
| BACnet communication | |||||||||
| PROFINET slave communication | |||||||||
| BACnet register exchange | |||||||||
| PROFINET register exchange | |||||||||
| DMX master communication | |||||||||
| Communication speed 250 kbaud | |||||||||
| Selectable baud rate from 1200 to 115200 baud | |||||||||
| Selectable baud rate from 3000 to 38400 baud | |||||||||
| Ethernet communication port (IEEE 802,3), RJ45 connector | |||||||||
| M-Bus communication port | |||||||||
| Device addressing from 1 to 250 | |||||||||
| Device addressing from 0 to 250 | |||||||||
| Device addressing from 0 to 512 | |||||||||
| Coil, Input, Holding Register e Input Register data exchange | |||||||||
| Single and multiple register reading/writing | |||||||||
| Writing of 1-byte registers to up to 512 DMX devices | |||||||||
| Volatile buffer memory, 1440-byte “Modbus image” buffer | |||||||||
| Volatile buffer memory, 1440-byte “BACnet image” buffer | |||||||||
| Volatile buffer memory, 1440-byte “M-Bus image” buffer | |||||||||
| Volatile buffer memory, 1440-byte “PROFINET image” buffer | |||||||||
| KNX TP (Twisted Pair) communication port at 9600 baud | |||||||||
| 1440-byte volatile support “KNX image” memory buffer | |||||||||
| Additional configuration program | |||||||||
| Mounting on 35 mm standard rail (EN 60715) | |||||||||
| DALI communication protocol | |||||||||
| 64 variable-address ballasts | |||||||||
| 128 variable-address ballasts |
09 DIN rail modules
Metering.
Compare the models.
| 4 models | ||||
|---|---|---|---|---|
| Three-phase metering | ||||
| Single-phase metering | ||||
| Direct insertion | ||||
| Bidirectional 4-quadrant measurement of all energies and powers | ||||
| Measurement of all the main parameters needed for consumption analysis | ||||
| For three-wire networks with balanced or unbalanced load | ||||
| Class B according to EN 50470-3 | ||||
| Tariff input | ||||
| 2 S0 outputs for energy pulse retransmission | ||||
| LCD display | ||||
| Sealable terminal cover | ||||
| MID certificate | ||||
| KNX protocol | ||||
| Mounting on 35 mm standard rail (EN 60715) |
10 DIN rail modules