Interface CF2 for load monitoring and control

DIN-Rail mount modules

CODE: EK-CF2-TP

Description

The Ekinex® EK-CF2-TP interface for load monitoring and control is a KNX devices which can be used to:

  • measure the instantaneous current absorbed by (up to) three single-phase or one three-phase electrical circuits; 
  • control electrical loads with priority disconnection and reconnection.

The current measurement is performed by means of max three Ekinex® EK-TA-... current transformers. The device is powered by the KNX bus and does not require auxiliary power supply. Flush-mounting or mounting on a standard 35 mm DIN-rail by means of a support included in the delivery.

Load monitoring
  • Direct measurement of instantaneous current by means of transformers EK-TA-...
  • Calculation of instantaneous power
  • Total electricity metering
  • Sending on the bus of measured current, power and energy values
Load control
  • Possibility to independently handle up to 8 loads for each channel
  • Configurable power threshold for load control and related hysteresis
  • Sending on the bus of an indication when the threshold is reached
  • Possibility to exclude loads from the bus
  • Disconnection and reconnection delay independently configurable for each channel
Power supply
  • 30 Vdc power supply by KNX bus
  • Current consumption from bus < 10 mA
Delivery

Delivery includes a terminal block for connection to the bus and a support for mounting on a standard 35 mm DIN-rail. Current transformers EK-TA-... (page 151) must be ordered separately.

Functions / Features
  • Plastic casing
  • Programming pushbutton and LED on the case
  • Connection to bus line with KNX terminal block
  • Connection to current transformers by means of a 6-wire screw terminal block
  • IP20 protection degree (installed device)
  • Weight 20 g
  • Connection to current transformers EK-TA-... by means of 3 physical inputs
  • Possibility to measure (up to) three single-phase or one three-phase lines; 
  • Possibility to receive power values from bus
  • 8 general purpose power thresholds
  • 4-channel logic functions (AND, OR or XOR)
Configurationa and commissioning

A detailed description of the parameters can be found in the application manual of the device. Configuration and commissioning require ETS5 2.0 or later versions. ETS application program: APEKCF2TP##.knxprod (## = release).

This website or its third party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the cookie policy. By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.